onsdag 25 maj 2016

Torra fakta om fukt och elektroosmos.

Utvärdering av uttorkning av fukt i betongväggar med aktiv elektroosmos.
Stephan Mangold, Chalmers Industriteknik, 2016-04-04
"Testväggen har torkat ut och är torr, d.v.s. att resultatet underskrider Boverkets riktlinje för kritiskt fukttillstånd på 75 procents relativ fuktighet (RF%). Mätningarna visar dessutom att väggen blev successivt torrare under den tolvveckorsperiod som testet omfattade."
Klicka och läs 

Influence of electro-osmosis applied to concrete demoulding on its properties.
Ce Bian, Zhenghong Tian, Laong Mao & Kung Wu, Indian Journal of Engineering & Materials Sciences, October 2015. "The main objective of this study is to calrify how applied voltage in the process of removing formwork based on electro-osmosis effect affects concrete properties."
Klicka och läs 

Application of Electro-Osmosis to Combat Water Leakage in Aged Buildings.
Francis Lung, HKCI Annual seminar presentation, 2013-11-22.
Klicka och läs 

Electroosmotic Pulse Technology to Control Water in Varied Construction Media.
Vincent F. Hock m.fl. 219th ECS Meeting, The Electrochemical Society, 2011."Because of challenges to develop and commercialize EOPtechnology, private industry has been involved since 1994. Various commercial partnerships, especially the most recent between Electrotech CP and ERDC, have resulted in successful field demonstrations of EOPtechnology in military, government, and commercial buildings including basements, tunnels, parking garage,and munitions bunkers. The latter proved the electrical component could be adapted for use in a potentiallyexplosive environment. EOP technology has been successfully implemented on USACE Civil Works structures such as lock walls and is being considered by the Bureau of Reclamation for use in galleries of high head power dams.
Klicka och läs

Utbedring av fuktskadede kjelleryttervegger. Delrapport 1 - Litteraturundersøkelse og generelle anbefallninger. Prosjektrapport 83.Stig Geving og Peter Blom, SINTEF Byggforsk. 2011. "Det synes dokumentert at velfungerende aktive elektroosmosemetoder vil kunne gi en uttørking av fuktige konstruksjoner mot grunnen."
Klicka och läs

God bebyggd miljö - förslag till nytt delmål för fukt och mögel. Resultat om byggnaders fuktskador från projekt BETSI.
Boverket, december 2010.
Klicka och läs

Laboratory Testing of Electro-Osmotic Pulse Technology to Reduce and Maintain Low Moisture Content in Concrete.
Orange S. Marshall, Vincent F. Hock, Brendan J. Danielson and Katherine A. Masko. 2009 Army Corrosion Summit, Clearwater Beach, Fl. 2009-01-06."When the anodes are placed interior to the concrete with the cathodes near the surface where water can penetrate, EOP will block water entry into the interior of the concrete."
Klicka och läs 

Demonstration of Electro-Osmotic Pulse Technology in Earth-Covered Magazines at Fort A.P. Hill, VA.
Final Report on Project FAR-01 for FY06. Orange S. Marshall, Jr. Augusti 2009. "Electro-Osmotic Pulse (EOP) technology can reverse below-grade water intrusion through concrete pores. It has been successfully installed in military infrastructure ranging from family housing to steel-reinforced deep structures and tun-nels. EOP has been shown to prevent below-grade moisture seepage through concrete and keep interior concrete spaces at or below 50 percent relative humidity."
Klicka och läs

Electro-Osmosis Using Multi Pulse Sequencing for Removing and Repelling Water out of Buildings and Other Structures.
Christopher Stanley, Ian McFeat-Smith, 33d Conference on Our World in Concrete & structures, 25-27 August 2008, Singapore. "Electro-osmosis is a well proven method of driving moisture out of concrete. The power consumption for its ongoing operation is minimal, at about 10 watts per 1000m2 of the concrete area. Its use will help to prevent steel corrosion and the occurrence of alkali-aggregate reaction. Because it reduces the moisture in basements it reduces the corrosive environment for plant and equipment. It also prevents the occurrence of mould and bacteria formation on damp wall surfaces. In addition some of the other benefits are listed below."
Klicka och läs 
Svensk sammanfattning av rapporten ovan

Electrical pulses protect concrete.
Joost van Kasteren, Delft Outlook, 2006
Klicka och läs

Fuktmåling i kjellerlokale. Bygg 5461, Nygårdsgata 55, Fredrikstad.
Byggforsk (Norges byggforskningsinstitutt) Projekt nr O 10318, 2006-10-14. "NBI konkluderer med at Elektroosmoseanlegget i Nygårdsgaten 55, Fredrikstad, bidrar til å markant redusere fuktnivået i betongen. Det anbefales å fortsatt holde anlegget operativt, da en nedkopling/svikt i anlegget vil medføre at fukten i betongen igjen vil stige.
Klicka och läs 

Fuktmätning i betong.
Hans Fredin, Håkan Skoog. Lunds Tekniska Högskola, 2005.
Klicka och läs

Evaluation of Lectros Dampcoursing System - Old Adelaide Gaol.
James p. Mann & Michael Till. Report 2AM1620, 2003-03-28. "Comparison of the drying characteristics of the Lectros test panel with the Untreated (NT) panel shows that the Lectros system has had a dramatic effect in reducing the moisture content of the wall (this can be seen clearly in Figure 3). By the end of the investigation the Lectros panel was considered to be in a “dry” state; this conclusion was confirmed by analysis of drillings from the mid-thickness of the wall. In comparison, the Untreated panel was found "to still have a moisture content of 8% at a height of 46cm above ground level.
Klicka och läs

Electro-Osmotic Pulse (EOP) Technology for Control of Water Seepage in Concrete Structures,
Michael K. McInerney m .fl.  US Army Corps of Engineers, Engineering Research and Development Center, August 2002. "Electro-osmotic pulse (EOP) technology offers an alternative to the trench-and-drain approach by mitigating water-related problems from the interior (negative side) of affected areas without the cost of excavation. EOP technology can also mitigate cor-rosion damage to mechanical equipment and improve indoor air quality by control-ling the relative humidity (RH) on the interior wall and floor surface at a level be-low 55 percent, thus eliminating mold and bacteria growth."
Klicka och läs
Svensk översättning av rapporten ovan

Electro-Osmotic Pulse Technology for Control of Groundwater Intrusion in Concrete Structures.
2002 Nova Award Nomination 26. Construction Innovation Forum.  ElectroOsmotic Pulse (EOP) technology is based on the concept of electroosmosis; the movement of an electrically charged liquid under the influence of an external electric field. It not only eliminates water-seepage problems from the interior of the structure without excavation, but it further mitigates corrosion damage to mechanical equipment and reduces the interior relative humidity of the basements. The reduction in relative humidity or moisture content of the concrete interior surface also eliminates one of the primary sources of disease
carrying molds and bacteria, which require a high moisture content to survive."
Klicka och läs

Electroosmotic Bauwerkstrockenlegung (Building Berlin).
Dipl.Ing.Fritz Jürgen Braun, Bauing.Peter Pötzsch, Dipl.Ing.Günter Wagemann.
Klicka och läs

Bundesanstalt für Materialprüfung (BAM): Prüfung der Methode FEO-B nach Tenge zur elektro-physikalischen Mauerwerksentfeuchtung auf ihre Wirksamheit.
Nr 2/18776. Siemens AG.1978-06-16.
Klicka och läs

ÖNORM B 3355-2 Trockenlegung von feuchtem Mauerwerk - Maßnahmen gegen aufsteigende Feuchtigkeit im Mauerwerk. 1999-06-01
Klicka och läs

Demonstration of Electro-Osmotic Pulse Technology for Groundwater Intrusion Control in Concrete Structures.
Vincent F. Hock, Michael K. McInerney, and Erik Kirstein, U.S. Army Construction Engineering Research Laboratories Champaign, IL 61826-9005. FEAP Technical Report, April 1998. "Based on the results of demonstrations and validations, this study concludes that the application of EOP technology for control of water seepage in concrete basement structures is an acceptable alternative to conventional trenching and tiling." "It is recommended that the EOP technology be transferred for Army-wide implementation as a cost effective alternative to the “trench/drain” approach for control of moisture in concrete basement structures.
Klicka och läs 

Kritiska fukttillstånd för några byggnadsmaterial. Preliminär undersökning.
Göran Hedenblad, Lars-Olof Nilsson. Rapport TVBM-3028. Lund, 1987.
Klicka och läs

A Review of Rising Damp in Masonry Buildings.
Dr Zhongyi Zhang, Advanced Polymer and Composites (APC) Research Group, Department of Mechanical and Design Engineering, University of Portsmouth, UK.
Klicka och läs

Uppstigande markfukt. Teknisk Rapport.
Jan Nyberg m.fl. SFV.
Klicka och läs

Tafjord Dam Case Study
Triton Norway
Klicka och läs

Donggang Cable Tunnel, Dalian, China Case Study
Triton Norway
Klicka och läs

Park West, UK, Case Study
Triton Norway
Klicka och läs

Sun Hung Kai/MTRC Case Study
Triton, Norway
Klicka och läs

Transport for London, Walthamstow Central Subway Case Study
Triton Norway
Klicka och läs

Drying brick masonry by electro-osmosis.
L.M. Ottesen and I. Rörig-Dalgård, Department of Civil Engineering, Technical University of Denmark.
Klicka och läs

Electro-Osmotic Pulse Leak Repair Method: Evaluation in Trinity Bonnet Chamber - Central Valley Project, Trinity River Division - California.
Daryl A. Little, Kurt F. von Fay, Bureau of Reclamation, Technical Services Center, Materials Engineering and Research Lab, Denver, CO, United States.
Klicka och läs